Working principle:
1) When the temperature of heat collector reaches the set value, the controller will make the circulation pump work automatically.
2) The circulation pump makes heat-conducting liquid circulate automatically.
3) The heat-conducting liquid transfers heat to water by the heat exchanger in the tank.
4) In case the teperature of the circulation pump does not reach the set value, the circulation pump will be shut automatically.
5) In case the temperature of the tank does not reach maximum temperature, then start the auxiliary heating device.

Structure:
The seperated pressurized solar water heater is composed by heat controller, storage tank, controller, working station and installation parts.

Specification:
Model NO.
SBT-SP01
Vacuum Tube Heat
D47"L1500mm/D58"L1800mm
With straight copper heat pipe 
Inner Tank Materia & Thickness
Imported SUS304 Stainless ;
2mm
Bracket material & thickness
Aluminium alloy;
1.8mm
Outer tank Materia & thickness
Galvanized steel alloy;
0.4mm
Heat insulation layer Materia & thicknessl
Imported polyurethane;
50mm
Tube Hail Resistence
<=25mm
Cold resistance
-30
Working temperature
99 celsius degree
Stagnation temperature
300
Working pressure
1.0Mpa(10bar)
capacity
150,200,250,300,500L